Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arq. bras. cardiol ; 115(3): 515-524, out. 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131307

ABSTRACT

Resumo Fundamento A intervenção percutânea em pacientes com disfunção de prótese biológica mitral apresenta-se como uma alternativa ao tratamento cirúrgico convencional. Objetivo Relatar a primeira experiência brasileira de implante transcateter de bioprótese valve-in-valve mitral via transeptal (TMVIV-via transeptal). Métodos Foram incluídos pacientes portadores de disfunção de bioprótese cirúrgica submetidos ao TMVIV-transeptal em 12 hospitais brasileiros. Foram considerados estatisticamente significativos valores de p<0,05. Resultados Entre junho/2016 e fevereiro/2019, 17 pacientes foram submetidos ao TMVIV-via transeptal. A mediana de idade foi 77 anos (IIQ,70-82), a mediana do escore STS-PROM foi 8,7% (IIQ,7,2-17,8). Todos os pacientes tinham sintomas limitantes de insuficiência cardíaca (CF≥III), tendo 5 (29,4%) sido submetidos a mais de uma toracotomia prévia. Obteve-se sucesso do TMVIV-via transeptal em todos os pacientes. A avaliação ecocardiográfica demonstrou redução significativa do gradiente médio (pré-intervenção, 12±3,8 mmHg; pós-intervenção, 5,3±2,6 mmHg; p<0,001), assim como aumento da área valvar mitral (pré-intervenção, 1,06±0,59 cm2; pós-intervenção, 2,18±0,36 cm2; p<0,001) sustentados em 30 dias. Houve redução significativa e imediata da pressão sistólica de artéria pulmonar, com redução adicional em 30 dias (pré-intervenção, 68,9±16,4 mmHg; pós-intervenção, 57,7±16,5 mmHg; 30 dias, 50,9±18,7 mmHg; p<0,001). Durante o seguimento, com mediana de 162 dias (IIQ, 102-411), observou-se marcada melhora clínica (CF≤II) em 87,5%. Um paciente (5,9%) apresentou obstrução de via de saída de ventrículo esquerdo (VSVE), evoluindo para óbito logo após o procedimento, e outro morreu aos 161 dias de seguimento.Conclusão: A primeira experiência brasileira de TMVIV-transeptal demonstra a segurança e a efetividade dessa nova técnica. A obstrução da VSVE é uma complicação potencialmente fatal, reforçando a importância da seleção dos pacientes e do planejamento do procedimento. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Percutaneous intervention in patients with bioprosthetic mitral valve dysfunction is an alternative to conventional surgical treatment. Objectives To report the first Brazilian experience with transseptal transcatheter bioprosthetic mitral valve-in-valve implantation (transseptal-TMVIV). Methods Patients with surgical bioprosthetic dysfunction submitted to transseptal-TMVIV in 12 Brazilian hospitals were included. The significance level adopted was p<0.05. Results From June/2016 to February/2019, 17 patients underwent transseptal-TMVIV. Their median age was 77 years (IQR,70-82) and median Society of Thoracic Surgeons predicted risk of mortality (STS-PROM) score was 8.7% (IQR,7.2-17.8). All patients had limiting symptoms of heart failure (FC≥III) and 5 (29.4%) had undergone more than one previous thoracotomy. Transseptal-TMVIV was successful in all patients. Echocardiographic assessment showed a significant reduction in mean mitral valve gradient (pre-intervention, 12±3.8 mmHg; post-intervention, 5.3±2.6 mmHg; p<0.001), in addition to an increase in mitral valve area (pre-intervention, 1.06±0.59 cm2; post-intervention, 2.18±0.36 cm2; p<0.001) sustained for 30 days. There was a significant and immediate reduction in the pulmonary artery systolic pressure, with an additional reduction in 30 days (pre-intervention, 68.9±16.4 mmHg; post-intervention, 57.7±16.5 mmHg; 30 days, 50.9±18.7 mmHg; p<0.001). During follow-up (median, 162 days; IQR, 102-411), significant clinical improvement (FC≤II) was observed in 87.5% of the patients. One patient (5.9%) had left ventricular outflow tract (LVOT) obstruction and died right after the procedure, and another died at 161 days of follow-up. Conclusion The first Brazilian experience with transseptal-TMVIV shows the safety and effectivity of the new technique. The LVOT obstruction is a potentially fatal complication, reinforcing the importance of patients' selection and of procedural planning. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aged , Aged, 80 and over , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/surgery , Prosthesis Design , Brazil , Cardiac Catheterization , Treatment Outcome , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
2.
Arq. bras. cardiol ; 115(4): 680-687, out. 2020. graf
Article in Portuguese | SES-SP, LILACS | ID: biblio-1131356

ABSTRACT

Resumo Fundamento O implante valvar aórtico percutâneo (TAVR, do inglês Transcatheter Aortic Valve Replacement) reduz a mortalidade de pacientes portadores de estenose aórtica grave. O conhecimento da distribuição da pressão e tensão de cisalhamento na parede aórtica pode ajudar na identificação de regiões críticas, onde o processo de remodelamento aórtico pode ocorrer. Neste trabalho é apresentado um estudo de simulação computacional da influência do posicionamento do orifício valvar protético na hemodinâmica na raiz de aorta e segmento ascendente. Objetivos A presente análise apresenta um estudo da variação do padrão de fluxo devido a alterações no ângulo do orifício valvar. Métodos Um modelo tridimensional foi gerado a partir do exame de angiotomografia computadorizada da aorta de um paciente que foi submetido ao procedimento de TAVR. Diferentes vazões de fluxo foram impostas através do orifício valvar. Resultados Pequenas variações no ângulo de inclinação causaram mudanças no padrão de fluxo, com deslocamento na posição dos vórtices, na distribuição de pressão e no local de alta tensão cisalhante na parede aórtica. Conclusão Essas características hemodinâmicas podem ser importantes no processo de remodelamento aórtico e distribuição de tensão, além de auxiliar, em um futuro próximo, a otimização do posicionamento da prótese valvar percutânea. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model was generated from computed tomography angiography of a patient who had undergone a TAVR. Different mass flow rates were imposed at the inlet valve. Results Small variations of the tilt angle could modify the nature of the flow, displacing the position of the vortices, and altering the prerssure distribution and the location of high wall shear stress. Conclusion These hemodynamic features may be relevant in the aortic remodeling process and distribution of the stress mapping and could help, in the near future, the optimization of the percutaneous prosthesis implantation. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aortic Valve Stenosis/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement/adverse effects , Aorta , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Computed Tomography Angiography , Hemodynamics
4.
Arq. bras. cardiol ; 112(3): 292-301, Mar. 2019. tab, graf
Article in English | LILACS | ID: biblio-989329

ABSTRACT

Abstract Background: The choice of a mechanical (MP) or biological prosthesis (BP) for patients with valvular heart disease undergoing replacement is still not a consensus. Objective: We aimed to determine the clinical outcomes of MP or BP placement in those patients. Methods: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) that compared biological prostheses and mechanical prostheses in patients with valvular heart diseases and assessed the outcomes. RCTs were searched in the MEDLINE, EMBASE, LILACS, CENTRAL, SCOPUS and Web of Science (from inception to November 2014) databases. Meta-analyses were performed using inverse variance with random effects models. The GRADE system was used to rate the quality of the evidence. A P-value lower than 0.05 was considered significant. Results: A total of four RCTs were included in the meta-analyses (1,528 patients) with follow up ranging from 2 to 20 years. Three used old generation mechanical and biological prostheses, and one used contemporary prostheses. No significant difference in mortality was found between BP and MP patients (risk ratio (RR = 1.07; 95% CI 0.99-1.15). The risk of bleeding was significantly lower in BP patients than MP patients (RR = 0.64; 95% CI 0.52-0.78); however, reoperations were significantly more frequent in BP patients (RR = 3.60; 95% CI 2.44-5.32). There were no statistically significant differences between BP and MP patients with respect to systemic arterial embolisms and infective endocarditis (RR = 0.93; 95% CI 0.66-1.31, RR = 1.21; CI95% 0.78-1.88, respectively). Results in the trials with modern and old prostheses were similar. Conclusions: The mortality rate and the risk of thromboembolic events and endocarditis were similar between BP and MP patients. The risk of bleeding was approximately one third lower for BP patients than for MP patients, while the risk of reoperations was more than three times higher for BP patients.


Resumo Fundamento: A escolha de próteses mecânicas ou biológicas para pacientes com doença de válvula cardíaca ainda não é um consenso. Objetivo: Determinar os desfechos clínicos de próteses mecânicas e biológicas nesses pacientes. Métodos: Conduzimos uma revisão sistemática e metanálise e estudos controlados randomizados (RCTs) que compararam próteses mecânicas e biológicas em pacientes com doenças de válvulas cardíaca, e avaliamos seus resultados. A busca por RCTs foi feita nas bases de dados MEDLINE, EMBASE, LILACS, CENTRAL, SCOPUS e Web of Science (do início a novembro de 2014). As metanálises foram realizadas usando variação inversa com modelos de efeitos aleatórios. Usamos o sistema GRADE para avaliar a qualidade da evidência. Um valor menor que 0,05 foi considerado significativo. Resultados: Um total de quatro RCTs foi incluído na metanálise (1528 pacientes) com acompanhamento de 2 a 20 anos. Em três estudos, foram utilizadas próteses mecânicas e biológicas mais antigas, e em um estudo próteses contemporâneas. Não foi observada diferença de mortalidade entre os pacientes que receberam próteses mecânicas e biológicas (risco relativo, RR = 1,07; IC95% 0,99-1,15). O risco de sangramento foi significativamente mais baixo nos pacientes que receberam próteses biológicas que naqueles com próteses mecânicas (RR = 0,64; IC95% 0,52-0,78). Contudo, as reoparações foram mais frequentes em pacientes com próteses biológicas (RR = 3,60; IC95% 2,44-5,32). Não houve diferenças estatisticamente significativas entre pacientes com próteses biológicas e mecânicas em relação à embolia arterial sistêmica e endocardite infecciosa (RR = 0,93; IC95% 0,66-1,31; RR = 1,21; IC95% 0,78-1,88, respectivamente). Resultados entre os estudos com próteses modernas e antigas foram similares. Conclusões: A taxa de mortalidade e o risco de eventos tromboembólicos e endocardite foram similares entre os pacientes que receberam próteses biológicas e mecânicas. O risco de sangramentos foi aproximadamente um terço menor nos pacientes com próteses biológicas que mecânicas, ao passo que o risco de reoperação foi mais que três vezes maior nos pacientes com próteses biológicas.


Subject(s)
Humans , Heart Valve Prosthesis/standards , Heart Valve Diseases/surgery , Reoperation , Bioprosthesis , Randomized Controlled Trials as Topic , Treatment Outcome , Evidence-Based Medicine , Heart Valve Prosthesis Implantation/methods
SELECTION OF CITATIONS
SEARCH DETAIL